Skip to Content

Cells (GTEM; Laplace)

Laplace LaplaCell
EMC Test Cell for the rapid and efficient testing of products for EMC compliance
  • EMC cell with a dual-septum design
  • 30 MHz to 6 GHz
  • Test specimens up to 60 x 60 x 60 cm
Teseq GTEM 250
GTEM cell for emission and immunity testing
  • GTEM cell: Radiated immunity and emission tests in a shielded environment in accordance with IEC/EN 61000-4-20
  • Diaphragm height 250 mm, 50 Ω, DC–20 GHz, VSWR ≤ 1.45:1
  • DUTs measuring up to approx. 0.20 × 0.20 × 0.15 m with a defined, homogeneous field region
Teseq GTEM 750
Emission and immunity tests in a single, shielded environment
  • GTEM chamber: Radiated immunity and emission tests in a shielded environment in accordance with IEC/EN 61000-4-20
  • Septum height 750 mm, 50 Ω, DC–20 GHz, VSWR < 1.45:1, input power up to 200 W
  • EUT volume up to approx. 0.62 × 0.62 × 0.49 m with a homogeneous field zone
Teseq GTEM 1000
GTEM cell for emission and immunity testing
  • Radiated emissions and immunity tests in a shielded environment in accordance with IEC/EN 61000-4-20
  • Frequency range: DC to 20 GHz, 50 Ω, VSWR < 1.45:1, maximum input power 1000 W
  • Max. partition height 1000 mm; max. EUT dimensions approx. 0.74 × 0.74 × 0.66 m
Teseq GTEM 1250
GTEM chamber for emission and immunity testing with a septum height of 1,250 mm
  • GTEM cell: Electromagnetic immunity and emissions in a shielded environment in accordance with IEC/EN 61000-4-20
  • Dimensions/Performance: Septum height 1250 mm, 50 Ω, DC–20 GHz, VSWR < 1.45:1, up to 1000 W input power
  • Large test chamber for EUTs up to approx. 0.93 × 0.93 × 0.83 m with a homogeneous field area
Teseq GTEM 1500
GTEM chamber for emission and immunity testing with a septum height of 1,500 mm
  • GTEM chamber: Radiated immunity and emission tests in a shielded environment in accordance with IEC/EN 61000-4-20
  • Partition height 1500 mm, 50 Ω, DC–20 GHz, VSWR < 1.6:1, input power up to 1000 W
  • EUT volume up to approx. 1.11 × 1.11 × 0.99 m with a defined, homogeneous test area
Teseq GTEM 1750
GTEM chamber for emission and immunity testing with a septum height of 1,750 mm
  • GTEM cell: Electromagnetic immunity and emissions in a shielded environment in accordance with IEC/EN 61000-4-20
  • Diaphragm height 1750 mm, 50 Ω, DC–20 GHz, VSWR < 1.8:1 (typ. < 1.45:1), input power up to 1000 W
  • EUTs up to approx. 1.32 × 1.32 × 1.16 m with a homogeneous field region
Teseq GTEM 2000
GTEM chamber for emission and immunity testing with a septum height of 2000 mm
  • GTEM chamber: Radiated immunity and emission tests in a shielded environment in accordance with IEC/EN 61000-4-20
  • Diaphragm height 2000 mm, 50 Ω, DC–20 GHz, VSWR < 1.8:1 (typ. < 1.45:1), up to 1000 W
  • EUTs up to approx. 1.50 × 1.50 × 1.32 m with a homogeneous field region
Teseq SL 50 Stripline
Frequency range from 10 kHz to 1 GHz
  • Homogeneous RF field between two plates for immunity tests on EUBs and cables in accordance with ISO 11452-5
  • 10 kHz – 1000 MHz, plate spacing 150 mm, N-connector 50 Ω, VSWR typically < 1.3
  • Max. input power: up to 1000 W
Teseq SL 90 Stripline
Efficient power conversion delivers a high magnetic field with minimal power consumption
  • Stripline system
  • Narrowband RF tests with very low power consumption
  • Compliance with standard: ISO 11452-5
Teseq SL 150 Stripline
Frequency range from 10 kHz to 1 GHz
  • Homogeneous RF field between two plates for immunity tests on electrical/electronic sub-assemblies (EUBs) in accordance with ISO 11452-5
  • Plate spacing 800 mm, frequency range 10 kHz – 1000 MHz, 50 Ω N-type connector, max. 100 W input power
  • Specified in EU Directives 2004/104/EC, 2005/83/EC and 2009/0154
Teseq TPL 3000 Stripline
EMC tests for the immunity of vehicle components to RF fields
  • Tri-Plate system
  • 10 kHz–1 GHz
  • Plate spacing 300 mm
Teseq RC XS
Mode-stirring chambers – reverberation chambers for in-situ EMC tests
  • Emission and immunity tests in a shielded chamber in accordance with IEC 61000-4-21
  • 0.5 – 18 GHz
  • EUTs up to approx. 0.5 × 0.5 × 0.5 m
Teseq RC 2XS
Mode-stirring chambers – reverberation chambers for in-situ EMC tests
  • Field immunity and emission tests in a compact, shielded chamber in accordance with IEC 61000-4-21
  • 0.8–18 GHz
  • Internal volume for EUTs up to approx. 0.3 × 0.3 × 0.3 m