Skip to Content

Transient Generators (Burst, Surge)

EM Test NX5 Series
Modular compact generator up to 5.5 kV for burst, surge and power failure testing, with a library of standards
  • EFT/Burst up to 5.5 kV, Surge up to 5.0 kV, Power Fail in a single unit
  • Integrated CDN: Single-phase 400 V / 32 A, expandable to three-phase up to 200 A per phase
  • Peak measurement outputs (U/I), Opto-Link & Ethernet for remote operation
EM Test NX7 Series
Modular compact generator up to 7.0 kV for burst, surge and power failure ringwave
  • EFT/Burst up to 5.5 kV, Surge & Ringwave up to 7.0 kV, Power Fail, Telecom up to 7.0 kV
  • Integrated CDN: Single-phase, expandable to 3-phase up to 200 A per phase
  • Monitor outputs for peak U/I, Ethernet, USB, Opto-Link
EM Test NX8
Combination Wave Generator
  • Surge up to 8 kV (1.2/50 μs voltage, 8/20 μs current), EFT/Burst up to 8 kV, ring wave
  • Compliance with standards: IEC 61000-4-5, IEC 61000-4-4, IEC 61000-4-9, IEEE C62.41.2, EN 50121-3-2/3-4
  • Internal CDNs for single-phase and three-phase systems, variants up to 3×690 VAC and 1000 VDC, 16–32 A
EM Test CCI
Capacitive coupling section for burst testing on signal and data lines
  • Standard: IEC 61000-4-4, 3rd edition
  • Capacitive coupling terminal, active coupling length 1 m
  • Burst voltage up to 7 kV, for cables up to 40 mm in diameter
Teseq NSG 3040A
Modular compact generator up to 4.8 kV for burst, surge and power failure tests, with a library of standards
  • Surge, EFT/Burst and power quality tests in a single device, in accordance with current IEC/EN standards
  • Surge up to 4.8 kV, EFT/Burst up to 4.8 kV / 1 MHz, PQT up to 16 A / 300 V AC & DC
  • Changing parameters whilst a test is in progress, Ethernet / PC control
Teseq NSG 3060A
Modular compact generator up to 6.6 kV for burst, surge and power failure ringwave testing
  • Surge, ringwave, EFT/burst and power quality tests for CE and ANSI C62.41 requirements
  • Surge & ringwave up to 6.6 kV, EFT/burst up to 4.8 kV / 1 MHz, PQT up to 16 A / 300 V AC & DC
  • Parameter changes whilst the test is in progress, Ethernet / PC control, modular expansion
EM Test ST Series
Coupling/decoupling network for unshielded balanced lines (communication lines)
  • Standards: IEC/EN 61000-4-4 (burst), IEC/EN 61000-4-5 (surge), IEC/EN 61000-4-12 (ringwave)
  • Models for 4 or 8 cables
  • CDN type: DCD st for unshielded, balanced cables
EM Test SR Series
Coupling/decoupling networks for signal and data lines
  • CDN type: DCD sr for unshielded, unbalanced cables
  • Standards: IEC/EN 61000-4-4 (burst), IEC/EN 61000-4-5 (surge), IEC/EN 61000-4-12 (ringwave)
  • Versions for 4 or 8 cables
EM Test HSC 4–8
Coupling/decoupling device for unshielded and shielded high-speed communication lines
  • Data rate: up to 1,000 Mbit/s, PoE/PoE+ compatible, RJ45 sockets
  • Surge up to 3–4 kV (1.2/50 μs), burst up to 4 kV, ring wave up to 4 kV in accordance with IEC 61000-4-4/-5/-12
  • Coupling/decoupling network for shielded and unshielded data cables
EM Test PCD8-DC
High-power surge coupling network
  • CDN for high-current DC: Coupling/decoupling network for DC up to 1,500 V and up to 400 A
  • Common-mode coupling via 33 nF to DC+, DC– and PE
  • EFT/Burst up to 8 kV in accordance with IEC/EN 61000-4-4, including for ECE-R10 and IEC 61851-21
EM Test NX20
1.2/50 µs surge generator for testing solar modules
  • Surge generator: 1.2/50 μs, surge voltage up to 20 kV, compliant with IEC/EN 61730-1/-2
  • 11 selectable capacitance ranges from 20 nF to 170 nF
  • Peak voltage and current measurement