Skip to Content

RF Immunity Test Systems

Teseq NSG 4060B1
System for conducted low-frequency immunity from 15 Hz to 150 kHz for testing in accordance with IEC/EC 61000-4-16 and 4-19
  • Signal source + integrated power amplifier for 15 Hz–150 kHz
  • Compliance with standards: IEC/EN 61000-4-16, IEC/EN 61000-4-19 and IEC/EN 60255-26 Annex A
  • PC-independent, with optional remote control
Teseq NSG 4070C1
Teseq NSG 4070C1, test system for conducted RF in accordance with IEC 61000-4-6, with CDN and EM clamps
  • Integrated signal generator and power amplifier for 4 kHz to 1 GHz
  • Compliance with standards: IEC/EN 61000‑4‑6, IEC/EN 61000‑4‑3, IEC/EN 61000‑4‑20, IEC 62132, ISO 11452‑4, MIL‑STD‑461 CS114
  • 3 power metre inputs, 5.7″ TFT display
Teseq NSG 4070D
The new standard for conducted immunity testing
  • Integrated signal generator for 4 kHz – 1 GHz with AM/PM modulation
  • 3 external power meter inputs (4 kHz–1 GHz)
  • Remote Control and Report Generator included
Teseq KEMZ 801 EM Clamp
EM Clamp for testing in accordance with IEC 61000-4-6 for cables for which no CDN exists
  • EM clamp in accordance with IEC/EN 61000-4-6
  • 10 kHz – 1000 MHz, 50 Ω
  • High input power: up to 100 W