Teseq SL 50 Stripline
Frequency range from 10 kHz to 1 GHz
Technical highlights
- Homogeneous RF field between two plates for immunity tests on EUBs and cables in accordance with ISO 11452-5
- 10 kHz – 1000 MHz, plate spacing 150 mm, N-connector 50 Ω, VSWR typically < 1.3
- Max. input power: up to 1000 W
User highlights
- ✓ Extremely efficient
- ✓ Highly reproducible
- ✓ Automotive standard
Applications:
- Automotive Industry & Railway Technology
- Telecommunications
- Testing laboratories and certification bodies
- Semiconductor and Electronics Development
- Research and universities
The Teseq SL 50 Stripline is a compact solution for EMC immunity testing under controlled conditions. It has been specially developed for smaller test specimens and enables precise and reproducible testing in laboratory environments.
The Stripline generates a defined electromagnetic field, which enables a realistic simulation of external interference. This allows developers to analyse the immunity of electronic components at an early stage and implement targeted measures to improve it.
Thanks to its compact design, the Teseq SL 50 Stripline is particularly suitable for laboratories with limited space. At the same time, it offers high field homogeneity, which is crucial for accurate measurement results.
Integration into existing test set-ups is straightforward. The clearly structured design makes it easier to position the test specimen and ensures that test series are carried out efficiently.
Typical areas of application:
• EMC testing on small assemblies
• Tests carried out throughout the development process
• Laboratory applications
• Preliminary qualifications
The Teseq SL 50 Stripline is a reliable solution for precise EMC testing in a compact space. It supports efficient development processes and delivers consistent results to underpin informed decisions.
Technical properties and features of this product.
| Spezifikation | Wert |
|---|---|
| Frequency range | 10 kHz – 1,000 MHz |
| Standards | ISO 11452‑5 / IEC 61000‑4‑20 / CISPR 25 |
| Measurement principle | Stripline (TEM field between parallel plates) |
| Max. input power | up to 1000 W |
| Impedance | 50 ohms |
| VSWR | approx. 1:1.3 |
| Connection | N-type (female) |
| Plate spacing | 150 mm |
| Field strength requirements | approx. 0.1 W for 10 V/m |
| Dimensions | 4.3 x 1.5 x 0.17 m |
Download the product documents directly or request further documents.