Teseq GTEM 2000
GTEM chamber for emission and immunity testing with a septum height of 2000 mm
Technical highlights
- GTEM chamber: Radiated immunity and emission tests in a shielded environment in accordance with IEC/EN 61000-4-20
- Diaphragm height 2000 mm, 50 Ω, DC–20 GHz, VSWR < 1.8:1 (typ. < 1.45:1), up to 1000 W
- EUTs up to approx. 1.50 × 1.50 × 1.32 m with a homogeneous field region
User highlights
- ✓ Maximum size
- ✓ High testing efficiency
- ✓ Pre-compliance at laboratory level
Applications:
- Automotive Industry & Railway Technology
- Telecommunications
- Testing laboratories and certification bodies
- Semiconductor and Electronics Development
- Research and universities
The Teseq GTEM 2000 is one of the largest GTEM chambers for EMC testing in the field of field-bound immunity. It was developed to test large and complex test specimens under controlled conditions. Thanks to its exceptionally large test volume, it offers maximum flexibility for industrial applications.
The design of the Teseq GTEM 2000 ensures a very uniform field distribution throughout the entire chamber. This enables electromagnetic disturbances to be simulated precisely and the immunity of systems to be assessed reliably. The results are reproducible and comply with the requirements of international EMC standards.
A key advantage lies in the scalability of the applications. The GTEM 2000 can be integrated into a wide variety of test set-ups and supports automated test processes. When combined with state-of-the-art measurement technology and control software, this results in efficient and standardised test procedures.
Typical areas of application include:
• EMC immunity tests on large systems and installations
• Pre-compliance checks carried out throughout the development process
• Validation of complex electronic assemblies
• Quality assurance in industrial mass-production processes
The spacious design allows tests to be carried out under realistic conditions, without being constrained by limited space. At the same time, a consistently high standard of measurement quality is guaranteed.
The Teseq GTEM 2000 is the ideal solution for companies with the most stringent requirements for EMC testing. It enables precise analysis even with large test specimens and delivers lasting improvements to the efficiency of complex test processes.
Technical properties and features of this product.
| Spezifikation | Wert |
|---|---|
| Frequency range | DC – 20 GHz |
| Standard frequency range | 30 MHz – 3000 MHz (in accordance with IEC/EN 61000-4-20) |
| Cell type | GTEM cell |
| Measurement application | Emissions / Immunity to interference |
| Max. input power | up to 1000 W |
| Impedance | 50 ohms |
| VSWR | <1.8:1 (typically <1.45:1) |
| RF connection | N-type |
| Shielding attenuation | 60 dB (typically >80 dB) |
| Dimensions | 8.95 × 4.62 × 3.24 m |
Download the product documents directly or request further documents.
Request further documents