Teseq GTEM 1750
GTEM chamber for emission and immunity testing with a septum height of 1,750 mm
Technical highlights
- GTEM cell: Electromagnetic immunity and emissions in a shielded environment in accordance with IEC/EN 61000-4-20
- Diaphragm height 1750 mm, 50 Ω, DC–20 GHz, VSWR < 1.8:1 (typ. < 1.45:1), input power up to 1000 W
- EUTs up to approx. 1.32 × 1.32 × 1.16 m with a homogeneous field region
User highlights
- ✓ Maximum EUT size
- ✓ High efficiency
- ✓ Pre-Compliance Turbo
Applications:
- Automotive Industry & Railway Technology
- Telecommunications
- Testing laboratories and certification bodies
- Semiconductor and Electronics Development
- Research and universities
The Teseq GTEM 1750 is a large-volume GTEM cell for demanding EMC tests in the field of field-bound immunity. It has been specifically designed for applications in which large or complex test specimens need to be tested. At the same time, its design ensures a stable and uniform field distribution throughout the entire test area.
Thanks to the controlled guidance of electromagnetic fields, the Teseq GTEM 1750 delivers reproducible measurement results that comply with standards. The high field homogeneity is crucial for the valid assessment of the immunity of electronic systems. This also allows even complex assemblies to be reliably analysed and optimised.
The large chamber allows for flexible use to meet a variety of test requirements. Companies benefit from an efficient alternative to traditional anechoic chambers, without having to compromise on precision. It can be easily integrated into existing measurement technology and automated test processes, significantly reducing the amount of manual work required.
Typical areas of application include:
• EMC immunity tests in accordance with international standards
• Pre-compliance testing during development
• Validation of large-scale electronic systems
• Quality assurance and series production approval
Thanks to the expanded test capacity, even large-scale devices can be tested under realistic conditions. At the same time, the measurement quality remains consistently high, ensuring comparable results.
The Teseq GTEM 1750 is a high-performance solution for companies wishing to test large test specimens efficiently and in accordance with standards. It supports a structured test strategy and helps to shorten development times and minimise risks.
Technical properties and features of this product.
| Spezifikation | Wert |
|---|---|
| Frequency range | DC – 20 GHz |
| Standard frequency range | 30 MHz – 3000 MHz (in accordance with IEC/EN 61000-4-20) |
| Cell type | GTEM cell |
| Measurement application | Emissions / Immunity to interference |
| Max. input power | up to 1000 W |
| Impedance | 50 ohms |
| VSWR | <1.8:1 (typically <1.45:1) |
| RF connection | N-type |
| Shielding attenuation | 60 dB (typically >80 dB) |
| Dimensions | 7.87 × 4.10 × 2.94 m |
Download the product documents directly or request further documents.
Request further documents