Teseq GTEM 1250
GTEM chamber for emission and immunity testing with a septum height of 1,250 mm
Technical highlights
- GTEM cell: Electromagnetic immunity and emissions in a shielded environment in accordance with IEC/EN 61000-4-20
- Dimensions/Performance: Septum height 1250 mm, 50 Ω, DC–20 GHz, VSWR < 1.45:1, up to 1000 W input power
- Large test chamber for EUTs up to approx. 0.93 × 0.93 × 0.83 m with a homogeneous field area
User highlights
- ✓ Faster than an absorber hall
- ✓ Efficient amplifier requirements
- ✓ Ideal for pre-compliance
Applications:
- Automotive Industry & Railway Technology
- Telecommunications
- Testing laboratories and certification bodies
- Semiconductor and Electronics Development
- Research and universities
The Teseq GTEM 1250 is a high-performance GTEM cell for demanding EMC tests in the field of field-bound immunity. It has been designed for applications where larger test specimens and high demands on measurement accuracy are paramount. Thanks to its design, it offers an extended test volume whilst maintaining stable field quality.
The precise field distribution within the cell enables reproducible and standard-compliant measurements. Electromagnetic fields are applied specifically to the test specimen, thereby ensuring a reliable assessment of immunity. This is of particular importance in the case of complex electronic systems.
The Teseq GTEM 1250 can be flexibly integrated into existing EMC test environments. When combined with suitable signal sources, amplifiers and measurement systems, complete test set-ups can be realised. Automated test sequences increase efficiency and reduce potential sources of error.
Typical areas of application include:
• EMC immunity tests in accordance with standards
• Pre-compliance testing throughout the development process
• Validation of large-scale electronic systems
• Quality assurance and series production approval
The larger test environment allows for the examination of a wide variety of test specimens without having to compromise on field homogeneity. At the same time, the space required remains moderate compared to conventional test chambers.
The Teseq GTEM 1250 is a high-performance solution for companies that wish to carry out reliable and flexible EMC tests and streamline their testing processes.
Technical properties and features of this product.
| Spezifikation | Wert |
|---|---|
| Frequency range | DC – 20 GHz |
| Standard frequency range | 30 MHz – 3000 MHz (in accordance with IEC/EN 61000-4-20) |
| Cell type | GTEM cell |
| Measurement application | Emissions / Immunity to interference |
| Max. input power | up to 1000 W |
| Impedance | 50 ohms |
| VSWR | <1.45:1 |
| RF connection | N-type |
| Shielding attenuation | 60 dB (typically >80 dB) |
| Dimensions | 5.95 x 3.06 x 2.52 m |
Download the product documents directly or request further documents.
Request further documents