EM Test DPA 503N
Complete harmonics and flicker measurement system
Technical highlights
- 3-phase harmonics and flicker analyser (also 1-phase) in accordance with IEC 61000-3-2/-12, IEC 61000-3-3/-11
- 16-bit A/D, real-time kernel, seamless recording to internal hard drive
- Can be operated as a standalone unit or as a complete measurement system with the AIF 503N
User highlights
- ✓ Fully compliant with standards
- ✓ No measurement losses
- ✓ Efficient evaluation: Integrated analysis and reporting software
Applications:
- Automotive Industry & Railway Technology
- Telecommunications
- Military and security technology
- Testing laboratories and certification bodies
- Industry and Automation
The EM TEST DPA 503N AIF 503N is a professional measurement system for standard-compliant harmonic and flicker testing in the field of electromagnetic compatibility. The solution was specifically designed for EMC test laboratories, development departments and industrial quality assurance and supports reliable conformity testing in accordance with international standards.
The system combines the high-performance DPA 503N Harmonic and Flicker Analyser with the AIF 503N network simulator. This enables precise measurements of power system disturbances to be carried out and realistic test conditions to be created. Users benefit from high measurement accuracy as well as a stable and reproducible test environment for modern electrical and electronic products.
The EM TEST DPA 503N AIF 503N supports efficient test procedures through intuitive operation and extensive automation options. The measurement data can be quickly analysed and documented, which significantly speeds up development and certification processes. At the same time, the flexible configuration allows the system to be adapted to a wide variety of test requirements and product categories.
Thanks to its standard-compliant analysis of harmonic currents and flicker emissions, the system is ideally suited to manufacturers of electrical equipment who need to reliably meet international EMC requirements. The robust system architecture also ensures a high level of operational reliability in day-to-day laboratory use.
Typical areas of application:
• EMC conformity testing
• Harmonics and flicker analysis
• Certification and testing laboratories
• Development of electrical appliances
• Quality assurance and product testing
The EM TEST DPA 503N AIF 503N impresses with its precise measurement technology, standard-compliant test functions and efficient operation. For professional EMC applications, the system offers a high-performance and reliable solution for analysing mains disturbances and voltage fluctuations.
Technical properties and features of this product.
| Spezifikation | Wert |
|---|---|
| Frequency range | 15 Hz to 3,000 Hz |
| Voltage input | 10 to 530 Vrms (up to 4 kV peak) |
| Power input | up to 16/32/63/75 Arms internally / up to 140 Arms externally |
| Measurement channels | 6 (3x current / 3x voltage) |
| A/D resolution | 16-bit |
| Standards | IEC 61000-3-2 / -12 / -3-3 / -3-11 / 61000-4-7 / 61000-4-15 |
| Harmonic analysis | 1st to 50th harmonics |
| Flicker impedance | Zref / Ztest integrated (AIF 503N) |
| Interface | USB |
| Supply voltage | 85 to 255 VAC |