Skip to Content
Thermography / Construction and Building Services Engineering

FLIR Si2a-PD

Industrial acoustic imaging camera for the detection of partial discharges

The FLIR Si2-PD precisely locates and analyses partial discharges in electrical installations using acoustic imaging. Thanks to inspections carried out from a safe distance, automatic fault classification and AI-supported severity assessment, it supports predictive maintenance, reduces the risk of failure and enhances operational safety.
Technical highlights
  • 124 MEMS microphones
  • Long test distance: 0.3 m to 200 m
  • Detects errors that are up to 30 times smaller than in previous generations
User highlights
  • ✓ Early detection of critical defects
  • ✓ AI-based severity assessment
  • ✓ Efficient asset management
Applications:
  • Switchgear (medium and high voltage)
  • Substations
  • Transformers
  • High-voltage cables and cable systems
  • Energy supply companies
FLIR Si2a-PD

The FLIR Si2-PD is a specialised acoustic imaging camera designed for the rapid and precise detection, localisation and assessment of partial discharges (PD) in high-voltage and medium-voltage installations. Using 124 highly sensitive MEMS microphones, it makes acoustic emissions detectable and enables precise fault localisation even from long distances.

A key advantage of the FLIR Si2-PD lies in its combination of acoustic imaging and intelligent fault analysis. Partial discharges are visualised, localised and automatically classified directly within the camera image. In addition, an integrated AI-based severity assessment helps to prioritise maintenance measures and provides a sound basis for maintenance decisions.

The camera operates without physical contact and enables safe inspections from distances of up to 200 metres. This allows electrical systems to be monitored whilst they are in operation, without interrupting production or interfering with critical processes. This enhances staff safety whilst reducing the effort required for inspections.


Typical areas of application include:

  • Detection and localisation of partial discharges in electrical installations
  • Condition monitoring of high-voltage and medium-voltage infrastructure
  • Preventive and predictive maintenance
  • Assessment of insulation faults and the risk of failure
  • Inspections at energy supply and industrial facilities


The FLIR Si2-PD offers intuitive operation and comprehensive analysis functions directly on the device. Discharge types, severity levels and recommended actions are determined automatically and can be used for further documentation and report generation. In addition, acoustic and thermal data can be combined in joint reports.

Early detection of critical insulation faults can help prevent unplanned downtime, reduce maintenance costs and improve plant availability. At the same time, the camera helps businesses minimise risks and improve operational safety in the long term.

The FLIR Si2-PD is a high-performance solution for modern electrical maintenance and provides a reliable basis for decision-making to ensure efficient condition monitoring and failure prevention.

Technical properties and features of this product.

Spezifikation Wert
Acoustic measurement Real-time sound visualisation
Number of microphones 124 MEMS microphones
Frequency range 2 kHz to 130 kHz
Measuring distance 0.3 m to 200 m
AI Severity Assessment AI-based automated assessment with recommendations for action
Field of view (FOV) 75° diagonally
Enlargement 8x
Image resolution 1280 × 720 pixels
Protection class IP54
Operating temperature -10 °C to +50 °C