Technical highlights
- Frequency range: 10 Hz to 30 MHz
- Real-time FFT analysis
- Fibre-optic extensions 9030 / 9060 for 3 GHz, 6 GHz or 18 GHz
User highlights
- ✓ Maximum measurement speed
- ✓ Measurement reliability
- ✓ Modular and expandable
Applications:
- Telecommunications
- Military and security technology
- Testing laboratories and certification bodies
- Semiconductor and Electronics Development
- Research and universities
The Narda PMM 9010F measurement receiver is a versatile EMC receiver for measuring conducted and radiated emissions across a wide frequency range from 10 Hz to 18 GHz. It is particularly suitable for demanding applications in laboratories and development.
The instrument delivers precise measurement results across the entire spectrum and enables a detailed analysis of emissions. Thanks to its high dynamic range and sensitivity, even complex signal structures can be reliably recorded.
A key advantage of the Narda PMM 9010F measurement receiver lies in its flexibility. It meets a wide range of requirements and can be used for both pre-certification tests and formal EMC tests .
The intuitive operation and powerful software facilitate efficient measurement procedures. Results are clearly presented and can be used straight away for documentation and analysis.
Typical areas of application include:
• Measurement of line-source emissions
• Broadband EMC analysis
• Development and certification of electronic systems
• Use in testing laboratories
The Narda PMM 9010F measurement receiver enables comprehensive and reliable analysis of electromagnetic emissions.
For applications involving a wide frequency range and high accuracy requirements, this device offers a high-performance solution.
Technical properties and features of this product.
| Spezifikation | Wert |
|---|---|
| Frequency range | 10 Hz to 30 MHz (expandable to 3 / 6 / 18 GHz) |
| Extension | Expandable via external fibre-optic units |
| Standards | CISPR 16-1-1 / MIL-STD / IEC / EN |
| Measurement principle | FFT-based EMI receiver (real-time analysis) |
| Detectors | Peak / Quasi-Peak / Average / RMS / C-AVG / APD |
| Dynamic range | approx. 80–200 dB |
| IF bandwidths | 1 / 3 / 10 / 30 / 100 / 300 kHz + 10 / 100 Hz |
| Accuracy | ±0.8 to 1 dB |
| Interfaces | USB / RS-232 |
| Scan time | 0.1 to 20 s (scan) / full sweep < 25 s |